The TRIPP-LITE PDUMH15AT 8-Outlet Power Distribution Unit is a reliable solution for managing power distribution in your setup. With a maximum input current of 15A and voltage compatibility of 120V, this unit is compatible with Tripp Lite PDUMH15AT PDU Metered. The black rack-mountable panel features surge protection, LED display, and 8 outlets, making it suitable for computers, networking equipment, and other devices. Weighing 10 pounds and measuring 14.5 x 17.5 x 1.75 inches, this Tripp Lite power distribution unit is a quality choice for ensuring stable power supply in your workspace.
Features
● Federal Trade Agreements Act / TAA compliant for GSA schedule purchases
120V 15A Automatic Transfer Switch (ATS) / Local Metered rack PDU (rPDU) (Agency de-rated to 12A
continuous)
● Provides a redundant A/B power option for non-redundant networking equipment with a single input
power cord
● Digital display continuously reports total output power consumption in amps
● 1U horizontal rack-mount form factor; 14.5 in. / 36.8 cm depth
● 8 built-in NEMA 5-15R outlets
● Set of two 12 ft. / 3.6m NEMA 5-15P input cables support connection to separate PRIMARY and
SECONDARY power sources
● ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails
or becomes unstable, the ATS will switch to maintain output sourced from the secondary input cable
until power on the primary input is restored and stable
● ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS
Highlights
● Single phase 12A 120V Auto Transfer Switch / ATS PDU
● Enables redundant A/B power option for single-corded network devices
● Separate primary and secondary inputs connect to any two compatible power sources
● 1U horizontal rackmount; 2 NEMA 5-15P inputs; 8 NEMA 5- 15R outlets
● Two digit visual current meter reports equipment load in amps; Upgrade options available
● TAA Compliant
● Ffully redundant UPS protection when each cord is connected to a separate UPS system (in a twoUPS environment, the primary input cable must be supported by an online UPS with zero transfer time similar to SmartOnline series)
● Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported
● On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the
secondary source when unavailable or of lower quality than the primary source
● Super-fast switchover between primary and secondary power sources occurs in 2-7 milliseconds
● Built-in card slot supports optional SNMPWEBCARD or WEBCARDLX for permanent upgrade to a switched & monitored PDU system
● Outlets are factory programmed for sequential turn-on at 250 millisecond intervals when the PDU is first energized to prevent inrush-related equipment interaction on startup
● Front panel LEDs confirm power availability on both input lines
Package Includes
ATS / Local Metered PDU with attached 5-15P primary input cord